The testing department related to Milestone
conducts tests required for accessing the
performance of Curtain Walling, Cladding,
Windows and Door systems. The Management of
Milestone is committed to good professional
practice and ensures the quality of its testing
to achieve customer satisfaction. The
performance testing is carried out as per the
requirements of the customer using the methods
prescribed in the latest ASTM, BS and AAMA
Standards.
All personnel concerned with testing within the
laboratory are familiarized with the quality of
documentation and implementation of the policies
and procedures in their work. The testing
department complies with ISO 17025 standards and
NABL CRITERIA at all times to ensure the quality
of testing. In testing, the company will
encourage active participation of all employees
in quality planning and continuous improvement
efforts to meet all quality, service and cost
objectives.
The various performance tests carried out
include:
-
Laboratory Testing
-
Air Infiltration Test - ASTM E 283
-
Water Penetration Test ( Static ) - ASTM E
331
-
Water Penetration Test (Dynamic) - AAMA
501.1
-
Structural Test ( Wind load serviceability)
- ASTM E 330
-
Seismic Racking Test ( Floor Displacement )
–AAMA 501.4
-
Structural Proof Load Test ( 150% ) - ASTM E
330
-
Seismic Proof Test (150-200%) - ASTM 501.4
-
Structural Test for Window Washer Tie Back
Prior to production the mockup testing is called
for. The mockup drawings are reviewed and
approved to ensure that all typical system
details are covered for the test. Before
testing, the mockup is checked in installed
condition to confirm that the same is in line
with the approved drawing. After the successful
completion of the mockup test the necessary
design changes will be called for and revision
of the design changes will be reviewed by the
company before the clearance is given for
commencement of production |